Promesstec DMP Melt Pressure Transmitters: From Process Data to Order Code
Melt pressure transmitters fail quietly: they read plausible values while drifting, and nobody notices until a extruder line produces scrap. Promesstec's DMP series is built for exactly this environment — diaphragm temperatures up to 400 °C, ranges from 0–3.5 MPa up to 0–300 MPa, and an internal 80 % FS calibration signal that lets you verify the loop without a deadweight tester. Ordering one is a structured exercise, and the order code makes that visible: a code like DMP-F-14-6/18-35-M2 encodes every decision. Here is how to walk through it.
From Process Data to Order Code
- Pin down the real pressure range. DMP spans 0–3.5 MPa to 0–300 MPa (roughly 0–500 psi to 0–43,500 psi). Pick a range where your normal operating point sits in the middle third — accuracy is quoted as 1 % FS including linearity, repeatability and hysteresis, so an oversized range wastes resolution where you actually operate.
- Decide sensor or transmitter output. The plain DMP is a sensor: 3.33 mV/V or 2 mV/V bridge output, fed from 10 V DC (9–12 V). The DMP…B transmitter variants give 4–20 mA, 0–10 V or 0–5 V from a 24 V DC (12–36 V) supply. If the cable run exceeds a few meters or the signal lands on a PLC analog card, take the 4–20 mA transmitter — mV signals over long unshielded runs are how drift complaints start.
- Choose the process connection. Standard options are 1/2"-20 UNF, M14×1.5, M18×1.5 and M22×1.5; anything else is a custom build. On European extruders, M18×1.5 dominates; on imported US machines, expect 1/2"-20 UNF.
- Set the stem or capillary length. Rigid stems come in 6", 9" and 12" (152/230/305 mm); flexible capillary versions come in 18" and 30" (460/762 mm). Rigid is cheaper and more robust; capillary is for when the 15-5PH coated stainless diaphragm cannot sit flush against the melt channel or the gauge head needs to clear a guard.
- Confirm the temperature envelope. The standard diaphragm handles 400 °C process temperature — enough for most polymer melts. If your machine also measures barrel or die temperature, Promesstec's dual-function DMP-T variants combine pressure and a J/K/E thermocouple or Pt100 in one instrument, which saves a second hole in the melt channel.
- Use the built-in check signal at commissioning. Every unit carries an internal 80 % FS calibration signal, switchable without any external equipment. Record the loop reading at that signal when the sensor is new; a quarterly comparison catches zero drift long before it becomes scrap.
- Assemble the order code left to right. Electrical connection (5- or 6-pin connector), mounting thread, stem/capillary length, range, output and — where fitted — the temperature sensor type. The example code DMP-F-14-6/18-35-M2 reads: 5-pin connector, M14×1.5 thread, 6" stem with 18" capillary, 0–35 MPa range, 2 mV/V output. Writing the code out with the machine's datasheet beside you takes ten minutes and prevents the most common rework: a transmitter that fits the thread but not the wiring.
If your application is ordinary industrial pressure rather than melt — hydraulics, water stacks, compressors — the same Promesstec catalog covers it with the DMP320 stainless-cell transmitter (0–100 mbar to 0–600 bar, 0.1 % FSO, response ≤ 0.5 ms, Ex and SIL 2 options) and the DS200 electronic pressure switch with 1, 2 or 4 freely configurable PNP outputs on a 4-digit LED display. Same ordering discipline applies: range first, output second, connection third.