Ordering a Bernstein Guard-Locking Switch: Seven Decisions Before You Fill In the Code
Bernstein's guard-locking safety switches — the SLO, SLC and SLK series — all follow the same ordering logic: the switch body, the actuator head and the connection come together as a code, and every character in that code is a decision you make before ordering. The SLC, for example, holds 1500 N per EN ISO 14119, offers four slow-action contacts, and ships with an integrated manual release; but its solenoid voltage, contact configuration and head style all live in the part number. Walking the seven decisions in order keeps the order form honest.
Seven steps from hazard to order code
- Decide whether you need guard locking at all. If opening the guard mid-process is merely inconvenient, a plain safety switch with separate actuator is enough. If the hazard coasts down — a saw blade, a flywheel, a heated screw — EN ISO 14119 territory begins and a guard-locking device that holds the door closed until standstill is the right tool.
- Pick the locking principle. The suffix in the code splits the series: F versions lock by spring force (closed-circuit current principle — the door stays locked when power is lost, standard for machine safety) and M versions lock magnetically (open-circuit principle, typical for process protection where a lost supply should not trap the operator).
- Choose the series by space and environment. SLO is the compact newcomer at 30 × 30 × 135 mm with 3000 N holding force, RFID coding in three tamper-protection levels and IP69; the SLC is the robust metal-head standard with 1500 N and IP67; the SLK is the slimmest of the three for tight doors, also IP67. All reach PL e / Category 4 in appropriate circuits.
- Set the solenoid voltage. The SLC family order codes show 024, 110/120 and 230 variants — 24 V AC/DC is the default for machine-built safety circuits, 230 V AC suits retrofit cabinets with no spare 24 V rail. Getting this wrong is the most common return reason.
- Specify the contact configuration. Four slow-action contacts total, factory-combined as needed — codes like 11/11, 20/20 or 10/30 state how many contacts monitor the door and how many monitor the lock. The lock-monitoring contacts carry the ISO 14119 interlock symbol and are the ones that belong in the safety circuit; the rest feed diagnostics or a Tattletale-style annunciator. Contact ratings: AC-15 240 V / 1.5 A, DC-13 24 V / 1.5 A.
- Choose the connection and special options. Hardwired or M12 connector (the R4/R6 suffix), plus the optional emergency exit lever or external emergency release for cells where an operator can be inside. The head rotates 4 × 90° and accepts the actuator in five positions, which absorbs most mounting mismatches.
- Order the actuator head separately. This is the step that catches people: the head is a separate line item. ACS-1 is the proven straight head, ACF-1 the flexible head that compensates small vertical or horizontal misalignment, ACR-1 the small-radius head, ACC-1 the cross head for vertical or horizontal actuation. Bolt the switch with the door in final position, set the head to suit, and the B10D of 2 × 10⁶ cycles does the rest over a −25 °C to +55 °C service range.
Run the seven in order and the final code — something like SLC-F-024-11/11-R4 with an ACS-1 head — writes itself. The full datasheets and the safety technology catalog live on the Bernstein download portal, and every figure above comes straight from the official SLC and SLO documentation rather than distributor summaries.