FAQ

Home > Support > FAQ

Five Questions to Answer Before You Order an Ikron Hydraulic Filter

Author: EFFSEN AUTOMATION | HONGKONG | Date: 2026-11-29

Q: Where should the filter actually sit in my hydraulic circuit?

Wherever the damage would start. A suction filter (HF410 handles up to 300 l/min, the HF431/434/437 family up to 220 l/min) sits in the tank ahead of the pump and catches what would destroy it first. A return filter catches wear debris before it settles back into the tank — Ikron's return range runs from the compact HF532 (50 l/min) up to the HF570/575/578 family rated 1 200 l/min, all at 8 bar tank-friendly working pressure. Pressure filters are the third position: they protect the components immediately downstream, like servovalves, that never forgive a particle.

Q: How do I size one so it does not choke the line?

Take the maximum flow through that line, not the average. A return filter sized for the pump's nominal flow will bypass constantly on cold starts when oil viscosity spikes. As a working example: on a 200 l/min return line, the HF547 (200 l/min max) is the bare minimum and the HF554 (630 l/min) gives comfortable margin; on anything above 600 l/min you go straight to the HF570 family. Sizing generously also keeps the pressure drop low, which keeps the bypass valve closed and the oil actually filtered.

Q: My pressure line runs at 350 bar — which housing survives that?

Several. Here is the pressure-line map straight from Ikron's product data:

SeriesMax flowMax working pressure
HF72520 l/min350 bar
HF705115 l/min350 bar
HF71047 l/min250 bar
HF735150 l/min320 bar
HF745170 l/min320 bar
HF69090 l/min150 bar
HF749105 l/min420 bar
HF760450 l/min420 bar

Q: What is the deal with spin-on filters — are they just a convenience thing?

Mostly yes, and on small circuits that is a perfectly good reason. The HF620/625 spin-on series works on both return and suction lines (350 and 190 l/min respectively), and the HF650 handles 200 l/min at up to 35 bar. Element replacement is a one-hand job: unscrew the canister, screw on a new one, no housing to open and no spilled oil to mop out of the tank. On a machine with a dozen small power units in the field, technicians usually pick spin-on for exactly that reason.

Q: How will I know the element is clogged before something bad happens?

Ikron's housings accept clogging indicators in three flavours — purely visual (a pop-up flag you check on your rounds), electrical (a switch that raises an alarm in the PLC), and combined visual-electrical units. They trigger before the bypass valve opens, which is the point: a bypassing filter feels identical to a working one from outside the tank. Add a filler breather or air filter from the accessories range (HB, AF105/106) so you are not filtering the air that gets sucked into the tank on every thermal cycle, and a level gauge like the HL91/HL98 to keep an eye on the oil itself.