The Murphy Swichgage Paper Trail: Three Official Installation PDFs Worth Saving

Author: EFFSEN | HONGKONG | Date: 2026-11-26

Murphy by Enovation Controls has been building Swichgage instruments for decades, and most of what an installer needs never changes: a 1/8-27 NPT port, a pointer that meets an adjustable contact, and a pilot-duty circuit that must reach a magnetic switch or Tattletale annunciator. The paperwork is the same story. Three official installation PDFs cover the overwhelming majority of 2 in. and 2-1/2 in. dial applications, and each is a short, dense sheet worth keeping on the shop tablet.

The contact figures repeat across all three documents and are worth memorizing: face-adjustable pointer contacts are rated 2 A @ 30 VAC/DC (pilot duty only), while the internal snap-acting SPDT switches on PE and ABS models carry 3 A @ 30 VDC or 4 A @ 125 VAC. The reset differential on snap-switch models is roughly 10% of scale, and the standing advice on scale selection is identical everywhere: pick a range so your normal operating reading sits in the upper middle of the dial.

  1. 00-02-0162 — Pressure and Vacuum Dial Murphygage and Swichgage Instruments (20, 25, A20 and A25 Series). The base sheet for every 20/25-family pressure and vacuum model, including the ABS (Alarm Before Shutdown) variants with the internal pre-alarm snap switch. It also explains the grounding difference between the steel-case 20/25 series (contact circuit grounds through the case) and the polycarbonate A20/A25 housings (isolated ground via the C or P terminal), plus the mounting dimensions for all four series. Download the official installation instructions (PDF).
  2. 00-02-0168 — Temperature Dial Murphygage and Swichgage Instruments (20T, 25T, A20T and A25T Series). The vapor-tension equivalent for coolant, crankcase oil and transmission temperature. Key installation points: never cut or kink the capillary, coat the sensing bulb with high-temperature grease (silicone with graphite flakes), route the capillary away from exhaust manifolds, and remember that on adjustable switch versions the trip point is set only over the upper half of the temperature scale with a 1/16 in. hex wrench. Full wiring diagrams for pointer-contact, TE snap-switch and TABS pre-alarm models are included. Download the official installation instructions (PDF).
  3. 00-02-0164 — Installing a Transmission/Gear Pressure SWICHGAGE Using a Pulsation Dampener. The one-page application sheet that saves gearboxes and gages alike: it requires a Murphy PD2160 pulsation snubber in the pressure line at both the transmission and the instrument, stabilizes the readout through shift cycles, and notes that omitting it voids the warranty. It also describes pairing an ABS model with an SS300 speed switch so the low-pressure trip point can be bypassed during shifting and idle without losing protection. Download the official application note (PDF).

One habit ties the three sheets together: at every startup, hold the reset button until normal readings appear (or fit an external time delay), confirm the instrument actually indicates the monitored value, and treat the contact check — rotate until it touches the pointer, watch the shutdown, reset — as part of routine preventive maintenance rather than a repair task. The PDFs are hosted on the Enovation Controls document server, so links point directly at the manufacturer's originals.