ABB A260-30-11-80 Contactor
[pics:title]

ABB A260-30-11-80 Contactor

Date: 2025-04-16
Brand: ABB
Models: A260-30-11-80
Price: Phone or Email Inquiry

Do you have any questions about this product? Please contact our customer service by phone number +852 30623028 Or Quick Inquiry Form.

Product Overview

ABB A260-30-11-80 Contactor 

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz

Dimensions

Product Net Width:

140 mm

Product Net Depth / Length:

180.5 mm

Product Net Height:

227 mm

Product Net Weight:

5.4 kg

Technical

Number of Main Contacts NO:

3

Number of Main Contacts NC:

0

Number of Auxiliary Contacts NO:

1

Number of Auxiliary Contacts NC:

1

Number of Poles:

3P

Rated Operational Voltage:

Main Circuit 690 V

Rated Frequency (f):

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith):

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A

Rated Operational Current AC-1 (Ie):

(690 V) 40 °C 400 A

(690 V) 55 °C 350 A

(690 V) 70 °C 290 A

Rated Operational Current AC-3 (Ie):

(415 V) 55 °C 260 A

(440 V) 55 °C 240 A

(500 V) 55 °C 240 A

(690 V) 55 °C 220 A

(380 / 400 V) 55 °C 260 A

(220 / 230 / 240 V) 55 °C 260

Rated Operational Current DC-1 (Ie):

(110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

Rated Operational Current DC-3 (Ie):

(110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

Rated Operational Current DC-5 (Ie):

(110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

Rated Operational Power AC-3 (Pe):

(415 V) 140 kW

(440 V) 140 kW

(500 V) 180 kW

(690 V) 200 kW

(380 / 400 V) 140 kW

(220 / 230 / 240 V) 80 kW

Rated Breaking Capacity AC-3:

8 x Ie AC-3

Rated Making Capacity AC-3:

10 x Ie AC-3

Short-Circuit Protective Devices:

gG Type Fuses 500 A

Rated Short-time Withstand Current Low Voltage (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A

Maximum Breaking Capacity:

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A

Rated Insulation Voltage (Ui):

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):

Main Circuit 8 kV

Maximum Electrical Switching Frequency:

(AC-1) 300 cycles per hour

(AC-2 / AC-4) 150 cycles per hour

(AC-3) 300 cycles per hour

Mechanical Durability:

5 million