Which Leuze Photoelectric Sensor Fits the Job? Five Questions to Settle First

Author: EFFSEN AUTOMATION | HONGKONG | Date: 2026-11-16

Q: Do I really need a throughbeam sensor, or is retro-reflective good enough?

Mostly it comes down to dust and how long the gap is. A throughbeam pair (Leuze's LE receiver plus LS transmitter, the 318B series spans roughly 5.5 m in the standard versions) is the most reliable choice across long distances and in dusty, misty environments, because any interruption of the beam counts. A polarized retro-reflective sensor like the PRK28 or PRK318B needs only one side wired and a reflector opposite, and in a clean packaging hall it does the same job at half the mounting effort. Rule of thumb: two sides only if the environment or the distance forces you to.

Q: The catalogue distance is 0.2 m. Can I trust that at 0.2 m?

Treat catalogue figures as laboratory numbers. Leuze publishes guaranteed operating ranges per surface reflectivity — for example the FT318BI.3 energetic diffuse sensor reaches 215 mm on 90% white paper but only 125 mm on 6% black rubber. Keep at least 30% margin to your worst-case target, and always check the range against the darkest part you will actually run, not the whitest.

PrincipleTypical rangeWatch out for
Throughbeam (LE/LS 318B)up to ~5.5 mTwo-sided mounting and alignment
Polarized retro-reflective (PRK)0.02–4.5 mReflectors soiling; shiny flat targets need the polarization filter
Energetic diffuse (ET/FT 318B)a few mm to ~0.35 mRange shrinks on dark or rough surfaces
Diffuse with background suppression (HRTR)per model, adjustableUse when the background must be ignored, not the object

Q: A mirror-finished part keeps tripping my retro-reflective sensor. What now?

That is direct reflection beating the polarization filter. Swap to a throughbeam set if the space allows, or use a diffuse sensor with background suppression aimed at the part — it detects the object in front of a defined distance window and ignores what lies beyond. For glass and transparent film, Leuze makes dedicated versions; a standard diffuse sensor will silently miss clear targets.

Q: What electrical setup do the 318B-family sensors expect?

Standard across the family: 10–30 V DC supply, two transistor outputs (PNP or NPN variants), usually M12 connector, IP67 housings. Light switching or dark switching is set on the unit, and the energetic diffuse models carry a teach button. Just confirm your PLC input cards match the PNP/NPN variant before ordering — that mismatch is the most common reason for a "dead sensor" that is actually a wiring logic problem.

Q: Anything special for tight spaces or washdown lines?

Yes. The series 20 flat and slim housings exist for installations where no cylindrical sensor fits, and they switch fast (0.5 ms response) so high-speed conveyors stay covered. For hygiene-sensitive or wet zones, look at the stainless 33C and 35C series with FDA-approved housing materials and wash-down design. Both keep the same wiring conventions as the rest of the range, so swapping one in rarely touches the control side.