Contrinex Inductive Sensors Compared: Full Inox, Extra Distance and the DMS Measuring Range
Most buyers come to Contrinex with the same problem: the sensor position sits inside a washdown line, a hydraulic cylinder body or a spot-weld cell, and the plastic-bodied sensor that worked on the bench dies within weeks. Contrinex builds every inductive sensor family around this reality, and the differences between the families are worth knowing before you order.
The core choice is between Classics (series 600, conventional design), Full Inox (series 700, one-piece V4A/AISI 316L stainless housing) and the special-duty variants: Extra Distance types with a ceramic active face for extreme pressure, and the DMS 750 measuring sensors that give a linear distance reading instead of a simple switch point. All Full Inox types carry IP68/IP69K, survive salt water and rate among the longest-lived inductive sensors on the market.
Series at a glance
| Series | Housing | Typical sizes | Sensing distances | Stand-out trait |
|---|---|---|---|---|
| Classics 600 | Plastic / stainless tube | M8, M12, M18, M30 | 1–20 mm embeddable | Best price, standard automation duty |
| Full Inox 700 | One-piece V4A (316L) | M8, M12, C23, M18, M30 | 1.5–20 mm embeddable | IP68/IP69K, salt-water proof, 800 bar peak on high-pressure M12 |
| Extra Distance | Stainless with ceramic face | M5–M14 | 1–3 mm, 2–3× standard reach | 1000 bar peak, 100 °C, IO-Link diagnostics |
| DMS 750 measuring | Stainless, digital chip | M8, M12, M18, M30 | 0–4 / 0–8 / 0–16 / 0–40 mm linear | Micron-level analog + IO-Link 1.1, all-metal targets |
- Washdown or food/pharma duty: pick Full Inox 700 — the welded 316L body has no seams for cleaning fluid to attack, and PNP versions include IO-Link.
- Pneumatic or hydraulic cylinder sensing over 500 bar: Extra Distance with the ceramic face, or high-pressure Full Inox M12 rated 500 bar continuous / 800 bar peak.
- Weld-splash and hot chips: Full Inox again — plastic housings are the first casualty in weld cells.
- Continuous gap, eccentricity or thickness measurement on steel, aluminum or brass: DMS 750 with teaching button, window logic and cycle counting over IO-Link.
One practical note when swapping Classics for Full Inox: the rated operating distances differ (for example 4 mm on a standard M12 versus 1.5 mm on the high-pressure Full Inox M12), so re-check the mounting drill depth before replacing like for like. If in doubt, the Contrinex online finder filters by size, material and pressure rating in one pass.



